Efficiency guaranteed
PMV and PM pumps ensure minimal crushing of the harvest. They have geared motors and a high-quality, FDA certified, rotor and stator assembly developed specifically by Bucher Vaslin.
Fitted with variable speed drives, they can be equipped with two level detectors for continuous operation.
User safety
Its safety features include a safety mechanism when running dry.
Easy maintenance
Delivered with an adapted washing grid, maintenance remains very limited and guarantees optimal hygiene.
Technical data | PMV 2 | PMV 4 | PMV 4 Var | PMV 4 var low capacity | PM6V mono 9kW | PM6V mono 11kW | PM6M mono 9kw | PM6M mono 11kW | PM6 var 6kw | PM6 Var 11kw | PM8 mono 11kW | PM8 mono 15kw | PM8 Var 11kw | PM10 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum capacity with destemmed grapes (t/h) | 20 | 30 | 10 to 30 | 3 to 16 | 60 | 60 | - | - | 30 to 60 | 30 to 60 | 80 | 80 | 40 to 80 | 130 |
Maximum capacity (t/h) with destemmed vatted pomace | 10 | 15 | 10 to 15 | - | - | - | 30 | 30 | - | - | 40 | 40 | 20 to 40 | 60 |
Length (mm) | 2254 | 2272 | 2272 | 2272 | 2250 | 2250 | 2250 | 2250 | 2750 | 2750 | 2820 | 2820 | 2820 | Sur mesure |
Width (mm) | 715 | 715 | 715 | 715 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | Made to measure |
Height (mm) | 970 | 1021 | 1021 | 1021 | 1021 | 1160 | 1160 | 1160 | 1160 | 1160 | 1160 | 1170 | 1170 | Made to measure |
Din 50F/Macon 50M
Motorized for Delta PM6 and Delta PM8
PMV intermediate grid for E2/F2 – E4/F4
- Equipped with electric safety interlock
- Required if used under a Delta E2, Delta Évolution 2, Delta E4, Delta Évolution 4
Intermediate PMV grid under F20
- Equipped with electric safety interlock
- Required if used under F20 gland
Intermediate grid. PMV for Oscillys 100/200
- Mandatory if used under an Oscillys
- Decanting grid for PMV
- Equipped with electric safety interlock
Height 250mm Delta PMV
Height 500 for Delta PMV, Delta PM6 and Delta PM8
PMV hopper height extension under Trio XL
With or without drip tray
Scanning level sensor HF PMV1/2/4
- Harvest settings
Scanning level sensor HF PMV1/2/4
- Pomace settings
Control console for HF level sensor
- 2 timed high and low level probes for Delta PM pump
Scanning sensor with pomace settings*
Scanning level sensor HF PMV1/2/4
- 24V
- Spherical outlet DN 120 M Delta PM6
- Spherical outlet DN150 M Delta PM6 and Delta PM8
For Delta PMV1VAR and PMV4VAR pumps with variable speed
Changing the position of the electrical box above the stator
Hopper PM 6 under Trio XXL without box
- With a standard hopper on the Trio XXL
PM 6 hopper under Trio XXL with box*.
- With screw-on drainage box on the Trio XXL
From performance to peace of mind, with Bucher Vaslin services.
Find a dealer
Selected for their professionalism, Bucher Vaslin dealers advise you and guarantee quality local service.
Join us
Interested in a career with Bucher Vaslin? Take a look at our job offers or apply directly on our website.